{"id":17006,"date":"2025-12-17T09:04:45","date_gmt":"2025-12-17T09:04:45","guid":{"rendered":"https:\/\/www.quantumrun.com\/consulting\/?p=17006"},"modified":"2025-12-17T12:28:11","modified_gmt":"2025-12-17T12:28:11","slug":"best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants","status":"publish","type":"post","link":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/","title":{"rendered":"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants"},"content":{"rendered":"\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"612\" height=\"408\" src=\"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2025\/12\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png\" alt=\"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants\" class=\"wp-image-17010\" srcset=\"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2025\/12\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png 612w, https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2025\/12\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants-300x200.png 300w\" sizes=\"(max-width: 612px) 100vw, 612px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Every piece of equipment is important when it comes to managing an industrial plant. However, some systems silently bear the burden of your entire operation, and dosing pumps are one of them. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These often overlooked components ensure that accurate chemical dosing supports water treatment, manufacturing, chemical processing, and other vital applications. In many facilities, a <strong>chemical dosing pump<\/strong> is fundamental to achieving stable treatment results.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Yet as regulatory expectations tighten and process automation becomes the new norm, aging dosing pumps are no longer just outdated hardware\u2014they can become systemic risks. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Inefficiencies, leaks, inconsistent dosing, and the inability to integrate with modern control systems can quietly undermine product quality, environmental compliance, and operational reliability. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Upgrading a dosing pump is increasingly part of a broader transition toward more reliable, precise, and digitally connected plant infrastructure.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Hidden Costs and Risks of Legacy Dosing Systems<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Like many forms of <a href=\"https:\/\/www.ato.com\/pumps\" class=\"external\"><strong>industrial pumps<\/strong><\/a>, legacy dosing pumps may feel like trusted old friends. You know their quirks, you\u2019ve patched them up many times, and they somehow get the job done. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But as plants grow and standards become more stringent, these pumps often introduce risks that directly affect production and safety.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Precision Drift and Inconsistent Dosing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wear, valve degradation, or stroke inconsistency can cause even a traditional <strong>diaphragm dosing pump<\/strong> to drift outside its expected accuracy range. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This may lead to product quality deviations, chemical overuse, or under-treatment that results in environmental non-compliance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Leakage and Seal Failures<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Aging diaphragms and seals greatly increase the chance of chemical leakage. Beyond cleanup and downtime, leaks can expose workers to hazardous substances and accelerate corrosion of surrounding equipment. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">According to <a href=\"https:\/\/www.osha.gov\/hazardous-materials\">OSHA guidelines on chemical handling<\/a>, even minor leaks from dosing equipment can elevate exposure risks and compromise workplace safety.\u00a0<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">High Maintenance Burden and Spare-Parts Uncertainty<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Older pumps often require frequent repairs and rely on spare parts that may no longer be readily available. This drives up maintenance costs and increases the likelihood of unplanned downtime.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Limited Data, Monitoring, and Integration Capabilities<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Legacy pumps typically lack communication capabilities and diagnostic features. Without data, plants cannot implement flow-paced dosing, predictive maintenance, or SCADA integration\u2014limiting modernization efforts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Modern <strong>chemical dosing pumps<\/strong> solve these problems by providing higher accuracy, improved safety, and better compatibility with automated systems.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">System Assessment Checklist: Identifying the Case for Upgrade<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Before deciding to upgrade, it\u2019s essential to evaluate the performance and condition of your existing pumps. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A structured assessment helps determine whether the pump still meets operational, regulatory, and safety requirements. Key evaluation areas include:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Performance<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Does the pump maintain the required flow accuracy (e.g., \u00b12% or better)?<br><\/li>\n\n\n\n<li>Are there signs of stroke inconsistency or cavitation?<br><\/li>\n\n\n\n<li>Does the pump lose prime or show unstable flow? In some cases, switching to a <strong>metering dosing pump<\/strong> may improve dosing stability and reliability.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Maintenance and Downtime<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>How many failures occurred in the past 12 months?<br><\/li>\n\n\n\n<li>How much downtime resulted from these issues?<br><\/li>\n\n\n\n<li>Are spare parts slow to source or discontinued?<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Leakage and Safety<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Any visible leaks or repeated seal failures?<br><\/li>\n\n\n\n<li>Does the system meet current ISO\/OSHA safety standards?<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Integration Requirements<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Is PLC\/SCADA connectivity needed?<br><\/li>\n\n\n\n<li>Does the process require flow-paced dosing or sensor feedback (pH, ORP, flow)?<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Chemical Compatibility<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Are pump materials (PTFE, PVDF, 316SS) still suitable for current and future chemicals?<br><\/li>\n\n\n\n<li>Have any formulation changes increased corrosion or wear?<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">If multiple categories show deficiencies, upgrading becomes not just beneficial but necessary.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Choosing the Right Modern Solution<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Modern <strong>metering and dosing pumps<\/strong> offer a range of enhancements, but selecting the correct model depends on linking pump capabilities to the challenges identified during assessment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Material Science and Durability<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PTFE, PVDF, engineered polymers, or alloy steel pump heads provide superior chemical resistance and extend service life, especially when handling aggressive chemicals such as those used in a <strong>chlorine dosing pump<\/strong> application.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Precision and Repeatability<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Advanced mechanical designs, digital stroke control, and advanced drive mechanisms found in higher-end industrial dosing pumps achieve accuracy of \u00b11% or better. This stabilizes dosing, reduces waste, and improves product consistency.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Digitalization and Smart Features<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Communication protocols such as Modbus, PROFINET, or 4\u201320 mA outputs enable monitoring, diagnostics, and integration with broader process control systems\u2014foundational for predictive maintenance and automation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Smaller automated systems\u2014such as <a href=\"https:\/\/www.ato.com\/dosing-pump\" class=\"external\"><strong>ATO chemical dosing pumps<\/strong><\/a>, known for their sensor-driven micro-dosing precision\u2014highlight how automation principles scale into industrial-grade pump technologies as well.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Safety and Compliance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Modern pumps meet the latest design and safety standards, and may incorporate leak detection ports, built-in protective valves, or ATEX certification for hazardous environments.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Are the Best Practices for Installation, Commissioning, and Integration?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Upgrading hardware is only the beginning; proper deployment ensures long-term performance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Professional Installation<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Verify NPSHa to prevent cavitation<br><\/li>\n\n\n\n<li>Support and align piping to prevent vibration<br><\/li>\n\n\n\n<li>Prevent air entrainment on the suction line<br><\/li>\n\n\n\n<li>Confirm chemical compatibility throughout the system<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Accurate Commissioning<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Calibrate using a calibration column or certified measurement<br><\/li>\n\n\n\n<li>Validate actual flow versus setpoint<br><\/li>\n\n\n\n<li>Test back-pressure and anti-siphon valves<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Integration With Control Systems<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Connecting the pump to PLC\/SCADA enables:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Flow-paced dosing<br><\/li>\n\n\n\n<li>Batch dosing sequences<br><\/li>\n\n\n\n<li>Closed-loop control based on pH, ORP, or residual measurements<br><\/li>\n\n\n\n<li>Centralized monitoring and alarm management<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Monitoring and Diagnostics<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Digital outputs allow operators to detect abnormal stroke patterns, pressure deviations, or motor load changes\u2014early signs of wear or pending failures.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Adopting a Predictive Maintenance Strategy<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Maintenance should shift from reactive repairs to lifecycle-based planning supported by data and routine inspections.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Routine Maintenance<\/strong>: Replace diaphragms, valves, and seals at recommended intervals to prevent unexpected failures.<br><\/li>\n\n\n\n<li><strong>Condition Monitoring<\/strong>: Monitor motor load, flow trends, and stroke-time variations to identify early signs of degradation.<br><\/li>\n\n\n\n<li><strong>Spare-Parts Strategy<\/strong>: Maintain essential OEM spare parts to minimize downtime and preserve pump accuracy.<br><\/li>\n\n\n\n<li><strong>Documentation and Continuous Improvement<\/strong>: Track maintenance records and failure events to optimize future maintenance cycles and guide pump selection decisions.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Enhancing Your Pump System with Automation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">As plants become more automated, dosing systems play a more dynamic role in process control. Modern automation enables:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Flow-paced adjustment to process variations<br><\/li>\n\n\n\n<li>Real-time remote monitoring<br><\/li>\n\n\n\n<li>Early alerts for leaks, wear, or inconsistent flow<br><\/li>\n\n\n\n<li>Feedback-based optimization using process sensors<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Automation reduces manual intervention, minimizes human error, and improves chemical usage efficiency.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">From Cost to Return on Investment (ROI)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Upgrading a legacy dosing system is not only a technical decision\u2014it delivers tangible financial benefits. Plants that transition to modern dosing pumps often achieve <strong>more stable dosing accuracy<\/strong>, which can reduce chemical usage by <strong>up to 10\u201315%<\/strong> in continuous processes. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Improved reliability helps eliminate recurring failures, cutting unplanned downtime by <strong>several hours per month<\/strong>, while extended maintenance intervals can trim annual service costs by <strong>20% or more<\/strong>. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Combined, these gains typically translate into a payback period of <strong>under one year<\/strong>, strengthening both operational efficiency and overall return on investment.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">By thoroughly assessing the condition of your existing system, selecting the right modern pump, installing it correctly, integrating it with control systems, and adopting a predictive maintenance approach, you transform a potential liability into a dependable and strategically valuable asset. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Upgrading a dosing pump is no longer just a hardware decision\u2014it is an investment in improved reliability, operational safety, product consistency, and long-term regulatory compliance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A modern dosing system is not merely an operational expense; it is a foundation for building a more resilient and future-ready plant.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Every piece of equipment is important when it comes to managing an industrial plant. However, some systems silently bear the burden of your entire operation, and dosing pumps are one of them. These often overlooked components ensure that accurate chemical dosing supports water treatment, manufacturing, chemical processing, and other vital applications. In many facilities, a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":17010,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[218],"tags":[],"class_list":["post-17006","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants<\/title>\n<meta name=\"description\" content=\"Every piece of equipment is important when it comes to managing an industrial plant. However, some systems silently bear the burden of your entire\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants\" \/>\n<meta property=\"og:description\" content=\"Every piece of equipment is important when it comes to managing an industrial plant. However, some systems silently bear the burden of your entire\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/\" \/>\n<meta property=\"og:site_name\" content=\"Quantumrun Foresight\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-17T09:04:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-17T12:28:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2025\/12\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png\" \/>\n\t<meta property=\"og:image:width\" content=\"612\" \/>\n\t<meta property=\"og:image:height\" content=\"408\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Richard Jaimes\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Richard Jaimes\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/\"},\"author\":{\"name\":\"Richard Jaimes\",\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/#\\\/schema\\\/person\\\/5a0afcb410d8e3137f58d5a201809011\"},\"headline\":\"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants\",\"datePublished\":\"2025-12-17T09:04:45+00:00\",\"dateModified\":\"2025-12-17T12:28:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/\"},\"wordCount\":1204,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/\",\"url\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/\",\"name\":\"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png\",\"datePublished\":\"2025-12-17T09:04:45+00:00\",\"dateModified\":\"2025-12-17T12:28:11+00:00\",\"description\":\"Every piece of equipment is important when it comes to managing an industrial plant. However, some systems silently bear the burden of your entire\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png\",\"contentUrl\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png\",\"width\":612,\"height\":408,\"caption\":\"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/#website\",\"url\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/\",\"name\":\"Quantumrun Foresight\",\"description\":\"Thrive from future trends.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/#organization\",\"name\":\"Quantumrun Foresight\",\"url\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/wp-content\\\/uploads\\\/2020\\\/07\\\/cropped-con-logo-00.png\",\"contentUrl\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/wp-content\\\/uploads\\\/2020\\\/07\\\/cropped-con-logo-00.png\",\"width\":286,\"height\":55,\"caption\":\"Quantumrun Foresight\"},\"image\":{\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/#\\\/schema\\\/person\\\/5a0afcb410d8e3137f58d5a201809011\",\"name\":\"Richard Jaimes\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/552ad8a69a374ceb309e1045d345be2d8c30e8a0e8cda42acb1fc357ca381509?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/552ad8a69a374ceb309e1045d345be2d8c30e8a0e8cda42acb1fc357ca381509?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/552ad8a69a374ceb309e1045d345be2d8c30e8a0e8cda42acb1fc357ca381509?s=96&d=mm&r=g\",\"caption\":\"Richard Jaimes\"},\"sameAs\":[\"https:\\\/\\\/www.quantumrun.com\\\/consulting\"],\"url\":\"https:\\\/\\\/www.quantumrun.com\\\/consulting\\\/author\\\/admin-stcons\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants","description":"Every piece of equipment is important when it comes to managing an industrial plant. However, some systems silently bear the burden of your entire","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/","og_locale":"en_US","og_type":"article","og_title":"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants","og_description":"Every piece of equipment is important when it comes to managing an industrial plant. However, some systems silently bear the burden of your entire","og_url":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/","og_site_name":"Quantumrun Foresight","article_published_time":"2025-12-17T09:04:45+00:00","article_modified_time":"2025-12-17T12:28:11+00:00","og_image":[{"width":612,"height":408,"url":"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2025\/12\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png","type":"image\/png"}],"author":"Richard Jaimes","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Richard Jaimes","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/#article","isPartOf":{"@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/"},"author":{"name":"Richard Jaimes","@id":"https:\/\/www.quantumrun.com\/consulting\/#\/schema\/person\/5a0afcb410d8e3137f58d5a201809011"},"headline":"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants","datePublished":"2025-12-17T09:04:45+00:00","dateModified":"2025-12-17T12:28:11+00:00","mainEntityOfPage":{"@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/"},"wordCount":1204,"commentCount":0,"publisher":{"@id":"https:\/\/www.quantumrun.com\/consulting\/#organization"},"image":{"@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/#primaryimage"},"thumbnailUrl":"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2025\/12\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png","articleSection":["Blog"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/","url":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/","name":"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants","isPartOf":{"@id":"https:\/\/www.quantumrun.com\/consulting\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/#primaryimage"},"image":{"@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/#primaryimage"},"thumbnailUrl":"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2025\/12\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png","datePublished":"2025-12-17T09:04:45+00:00","dateModified":"2025-12-17T12:28:11+00:00","description":"Every piece of equipment is important when it comes to managing an industrial plant. However, some systems silently bear the burden of your entire","breadcrumb":{"@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/#primaryimage","url":"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2025\/12\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png","contentUrl":"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2025\/12\/Best-Practices-For-Upgrading-Legacy-Dosing-Pumps-In-Industrial-Plants.png","width":612,"height":408,"caption":"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants"},{"@type":"BreadcrumbList","@id":"https:\/\/www.quantumrun.com\/consulting\/best-practices-for-upgrading-legacy-dosing-pumps-in-industrial-plants\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.quantumrun.com\/consulting\/"},{"@type":"ListItem","position":2,"name":"Blog","item":"https:\/\/www.quantumrun.com\/consulting\/blog\/"},{"@type":"ListItem","position":3,"name":"Best Practices For Upgrading Legacy Dosing Pumps In Industrial Plants"}]},{"@type":"WebSite","@id":"https:\/\/www.quantumrun.com\/consulting\/#website","url":"https:\/\/www.quantumrun.com\/consulting\/","name":"Quantumrun Foresight","description":"Thrive from future trends.","publisher":{"@id":"https:\/\/www.quantumrun.com\/consulting\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.quantumrun.com\/consulting\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.quantumrun.com\/consulting\/#organization","name":"Quantumrun Foresight","url":"https:\/\/www.quantumrun.com\/consulting\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.quantumrun.com\/consulting\/#\/schema\/logo\/image\/","url":"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2020\/07\/cropped-con-logo-00.png","contentUrl":"https:\/\/www.quantumrun.com\/consulting\/wp-content\/uploads\/2020\/07\/cropped-con-logo-00.png","width":286,"height":55,"caption":"Quantumrun Foresight"},"image":{"@id":"https:\/\/www.quantumrun.com\/consulting\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.quantumrun.com\/consulting\/#\/schema\/person\/5a0afcb410d8e3137f58d5a201809011","name":"Richard Jaimes","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/552ad8a69a374ceb309e1045d345be2d8c30e8a0e8cda42acb1fc357ca381509?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/552ad8a69a374ceb309e1045d345be2d8c30e8a0e8cda42acb1fc357ca381509?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/552ad8a69a374ceb309e1045d345be2d8c30e8a0e8cda42acb1fc357ca381509?s=96&d=mm&r=g","caption":"Richard Jaimes"},"sameAs":["https:\/\/www.quantumrun.com\/consulting"],"url":"https:\/\/www.quantumrun.com\/consulting\/author\/admin-stcons\/"}]}},"_links":{"self":[{"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/posts\/17006","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/comments?post=17006"}],"version-history":[{"count":1,"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/posts\/17006\/revisions"}],"predecessor-version":[{"id":17011,"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/posts\/17006\/revisions\/17011"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/media\/17010"}],"wp:attachment":[{"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/media?parent=17006"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/categories?post=17006"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.quantumrun.com\/consulting\/wp-json\/wp\/v2\/tags?post=17006"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}